EasyOne Pro LAB - Back side
EasyOne Pro LAB with arm and sensor

EasyOne Pro® LAB

Portable DLCO, MBW, Lung Volumes, LCI and Spirometry
EasyOne Pro LAB - Back side
EasyOne Pro LAB with arm and sensor

EasyOne Pro® LAB provides the most efficient and accurate way for complete lung function testing. With EasyOne Pro® LAB you can accurately measure the Lung Clearance Index (LCI) using Multiple Breath Nitrogen Washout (MBW) in any setting. Engineered using our patented TrueFlow™ and TrueCheck™ technology, the EasyOne Pro® LAB eliminates all common sources of error and saves time. No need for a Body Box.

  • Patient and User Centered Design
    The EasyOne Pro® LAB is both patient-friendly and easy to maintain. For MBW you only need an oxygen supply, no expensive SF6 gas required. Medical professionals can perform annual maintenance themselves in only 10 minutes.
  • Calibration-free TrueFlow™ Technology 
    Extremely robust and accurate flow results are delivered without calibration thanks to our TrueFlow™ technology integrated into the EasyOne Pro® LAB.
  • Self-Quality Control through TrueCheck™ Technology  
    With EasyOne Pro® LAB you can fully focus on the patient. TrueCheck™ ensures that each gas measurement is accurate without calibration and warm-up time.
  • Compact & Lightweight Design 
    Weighing only 18 lbs. (9kg), the EasyOne Pro® LAB is compact & durable – without compromising quality. It easily fits in any office setting.


 

Get more detailsEMR Connection Request
Why our customers love us

Details EasyOne Pro® LAB

Testing at the Point of Care

Get maximum efficiency and patient comfort in any setting. TrueFlow™ and TrueCheck™ ensure optimal results, independent of the clinician.

  • Always safe & ready to test with TrueCheck™
  • Diffusion capacity results in 3 minutes
  • User- and patient-friendly design
  • Ideal also for claustrophobic and obese patients
User instruction videos icon

Powerful Commenter

With our integrated commenter you can easily define standard comments and quickly add them to your patient's results.

  • Predefine comments
  • Quickly select or deselect
  • Quickly modify comments

Watch our video guide for more details.

EasyOne Pro Commenter

QC-Grading and Result Interpretation

Get automatic quality grading and interpretation based on NLHEP and ATS/ERS with the EasyOne Pro®.

  • Quality grades based on NLHEP and ATS/ERS for all tests
  • ATS/ERS interpretation decision tree
  • GOLD/Hardie, NICE, JRS and NLHEP
  • Diagnose Asthma, COPD, Emphysema and pulmonary vascular disorders

Encouraging Pediatric Incentives

With our simple but smart pediatric incentives children quickly understand what to do. This shortens your testing time and helps you achieve good quality spirometry results – and the children have fun doing the test. 

  • Birthday Cake incentive for FVC
  • Swinging Monkey incentive for FVC & FVL
  • Balloon incentive for FVC

Custom Provocation Protocols

Customize available standard provocation protocols for your needs or create your own. You can easily install the customized provocation protocol on your ndd devices.

  • Build your own provocation protocols
  • Modify existing provocation protocols
  • Export and load protocols onto other devices

Pre-installed protocols: Mannitol, MC, Exercise Provocation

Watch our video guide for more details.

Provocation Protocols

Customized Reports

Customize reports and chose the parameters to be displayed.

  • Arrange graphs, parameters and tests as needed
  • Choose which graphs to display
  • Freely define the tables including Z-score, % Predicted and LLN
  • Color reports for better visual clarity
     

TrueCheck™ – Always Safe & Ready to Test

TrueCheck™ takes care of the essential quality control for gas analysis testing. EasyOne Pro® is the only device proven to be accurate for a lifetime for DLCO measurements.

  • Calibration-free with proven long-term stability
  • Checks gas-sensor linearity and delay
  • Checks for leaks and gas concentration
  • Patented technology

To review case studies and additional information about our proven technology, please click here

TrueFlow™ - Trusted Ultrasound Technology

Stop worrying about calibration or accuracy of flow measurements.  TrueFlow™ is the only ultrasound technology proven to be accurate for a lifetime for flow and volume measurements.

To review case studies and additional information about our proven technology, please click here

EasyOne connect icon

Large Selection of Predicted Sets  (%Pred, Z-score and LLN)

The first in line for newly published predicted values: EasyOne® devices are  used  in predicted studies worldwide (e.g. LUNOKID, ALAT).

  • %Pred, Z-score, LLN
  • GLI (Stanojevic 2009, Quanjer 2012)
  • NHANES III (North America)
  • PLATINO (South America)
  • ERS (Europe) and JRS, IP, Chhabra (Asia)

Please see our specification below for a complete list of the supported predicted values.

Infection Control

ndd inline filter solutions provide additional COVID-19 protection for those who wish to include a filter when performing tests.  Filter options ensure reliable “double protection” from infection:

  • The filter keeps the ambient environment clean for technicians and patients
  • The spirette protects the flow sensor from contamination
  • Fully passes 24 Waveform tests as required by the ATS/ERS standard
  • Available for all testing environments where filters are required

Avoid cross-contamination and reduce cleaning to an absolute minimum:

  • All parts exposed to the patient's breath are single-patient-use
  • No sensor contamination possible
  • Only simple surface cleaning required of the device
  • No humidity can enter the device
  • No special storage conditions required for single-patient use spirettes and adapters
Elderly Woman Wearing Mask

EMR/EHR Connectivity and Centralized Data

Transmit and share data among ndd devices or to your Electronic Medical Record system.

  • Integrated into all major EMR/EHR systems via HL7, XML, GDT or API
  • References for integration available on request
  • Simple local or SQL server database
  • Review test results from any PC using EasyOne® Connect
EMR Graphic - With text

Printer and Network Connectivity

Stay connected and easily share data or print reports. EasyOne Pro® is equipped with a modern embedded PC solution that makes network and printer connections extremely easy and stable. 

  • USB / Network printer compatibility
  • Easily integrate into any network
  • USB, HDMI, Ethernet
  • Optional WiFi dongle
EasyOne connect logo

Cyber Security Protection for IT and Patient Information

Protect your patient information. EasyOne Pro® is a modern system designed to fulfill your cyber security needs.

  • Windows Defender Antivirus and Firewall
  • Operating system updates
  • Encrypted database export
  • User authentication with automatic log off
  • FDA Approval in 2017 with cyber security documentation
FDA HIPPA icon

Analysis and Recording of Raw Sensor Data

Go beyond normal lung function testing and get access to all raw data of any test collected. The tool WBreath is used in special study setups, but also by our support team.  

  • Access and measure raw data
  • Advanced Data Analysis
  • Fully integrated

Worldwide Compliance with Standards

Stay compliant with ATS/ERS standards and specific country regulations. 

  • Fully conformant to ATS/ERS and ISO standards
  • Worldwide approvals
  • CE Approval
  • FDA Approval
  • Japan Approval
     
Show other download categories
Videos
User Instruction
DLCO and FVL test with the EasyOne Pro - User instruction
Patient Instruction
Taking an MBW test with the EasyOne Pro (Patient instruction)
Patient Instruction
Taking a DLCO test with the EasyOne Pro (Patient instruction)
Patient Instruction
Taking an FVL test with the EasyOne Pro (Patient instruction)
Patient Instruction
Taking an SVC test with the EasyOne Pro (Patient instruction)
User Instruction
MBW and SVC tests with the EasyOne Pro - User instruction
Promotional
EasyOne Pro & Pro LAB - Simple. Certain. Proven.
Promotional
ndd @ ERS London 2016
Promotional
ndd @ ERS Amsterdam 2015
Promotional
Lung Clearance Index - Ready to use
Support
ndd Video Guide - How to Customize Provocation Protocols to Meet Your Needs
Support
ndd Video Guide - How to Define Texts & Interpretations Easily
Support
ndd Video Guide - How to Import External PFT
Support
ndd EasyOne Pro/Pro LAB - Replacement Parts Kit
Support
ndd EasyOne Pro/Pro LAB - Removing a Pressure Tube
Support
ndd EasyOne Pro/Pro LAB - Oxygen Gas Quick Connection Small E Tank
Support
ndd EasyOne Pro/Pro LAB - Oxygen Quick Connection Large H or K Tank
Show other download categories
Software
Please note that update can take up to 1 hour. This file includes operating system patches, please do not unpack zip file.

FAQs EasyOne Pro® LAB

The EasyOne Pro LAB is exactly the same as the EasyOne Pro, except that it has the capability to perform the multi-breath washout (MBW) test. This test requires additional sensors and the use of 100% Oxygen.

To add a filter (2) to the EasyOne Pro, insert the (1) Spirette FA Pro/LAB into the EasyOne Pro handle. Then attach the filter to the Spirette FA Pro/LAB, as shown in the diagram below. If you have questions about how to connect or use ndd filters, please contact ndd customer support in North America at [email protected] and internationally at [email protected].  

EasyOne Pro LAB inline filter solution

You can find the product specification on the respective product pages. The specification contains a list of all supported normal values.

To get more detailed information about the supported parameters, age range, ethnicities and height range of each supported predicted set, please click here.

The DLCO value can be adjusted for hemoglobin, altitude and the COHb concentration and CO back pressure.

Click here to find more information about the formulas used to derive DLadj.

Our research software WBreath can be used to perform a slope analysis. Please click here to get more information on this topic.

BTPS Correction is used to convert flow and volume measured at ambient conditions to the conditions within the lungs. Ambient conditions are called ATP (ambient temperature, pressure); the conditions within the lungs are called BTPS (body temperature, pressure, water vapor saturated).

Click here for more information.

Yes. Connecting the device to your network allows several additional benefits.

o Take advantage of your network data backup processes

o Print directly to your network printers

o Save reports electronically (such as PDF) directly to a network folder

o Connect with your EMR system

o Take advantage of a more powerful SQL Server database engine (click here for more detailled instructions)

o Connect multiple devices to a single, shared database

o Get access to the device database from your PC using our free EasyOne Connect PC software application

All EasyOne products are designed to require no calibration and minimal maintenance. The device is designed to remain in calibration throughout its lifetime. No calibration procedures are required prior to testing. Our TrueFlow ultrasonic technology assures accurate volume and flow measurements every time. And our unique automated TrueCheck process assures that all gas measurements are accurate for each test. You may choose to use the optional 3-liter calibration syringe to verify volume and flow accuracy, as recommended by ATS/ERS.

Yes. ndd’s products are all completely HL7 compatible enabling connectivity to virtually all EMRs. We would be happy to work with you to configure an interface for your particular EMR system. We are also constantly working to expand our library of dedicated integrations. For more information on connectivity with your particular EMR contact our Technical Support team.

A PFT session including spirometry and DLCO generally takes less than 20 minutes.

The EasyOne Pro/LAB is compatible with virtually all PC-style USB printers, without the need for external driver installation. The printer can be connected directly to a USB port on the rear of the device. We can sell you a printer with the device, or you can supply your own.

You can also connect the device to your network where it will automatically find any connected, compatible printers avoiding the need for a dedicated printer for your PFTs.

Spirette: Each test performed requires the use of a spirette. This is a single-patient-use mouthpiece which ensures that no contamination can reach the internal flow path of the device. This means that no cleaning is required between patients, and no calibration, ever. Simply toss the spirette after each test session.

Barriette: For a DLCO test, in addition to the spirette, you will need to use a barriette. This protects the valve and hose system from contamination, eliminating the need for cleaning between patients.

FRC barriette: This is similar to the DLCO barriette, but used only when performing a multi-breath washout test.

Gasses: The DLCO test requires a standard medical grade DLCO gas mixture consisting of 0.3% Carbon Monoxide, 10% Helium, 21% Oxygen, remainder Nitrogen. The multi-breath washout test requires 100% Oxygen. These gasses are readily available from your local medical gas supplier in various tank sizes. We will assist you in selecting the appropriate tank regulators required for connection to the device.

The device itself is self-contained and measures only 270 x 335 x 270 mm (10.6 x 13.2 x 10.6 inches) (h x w x d). No additional PC, monitor, keyboard or control unit is required. This allows it to easily fit on a counter. You will also need to allow for storage of the gas tank(s) which come in a variety of sizes, and can usually fit comfortably in a corner, or under the counter.

The EasyOne Pro/LAB is designed to require minimal maintenance. The annual replacement of four external components is ALL that is required to keep the system running smoothly. These components are available as a convenient kit. Installation is done in minutes and requires no special tools.

Data can safely be exported by using the “Export Data” feature or “Backup” feature within the Storage tab in the configuration.

Specifications EasyOne Pro® LAB

Quality, Medical Devices & Electrical
EN ISO 13485, EN ISO14971, EN 62366, EN 62304, EN ISO26782, EN ISO 23747, EN IEC 60601-1, EN IEC 60601-1-2
FDA
510(k) market clearance
MDD 93/42/EEC
CE marked
Associations &Institutes
ATS/ERS 2005, NIOSH/ OSHA, SSA Disability
Graphical user interface
Chinese, Danish, Dutch, English, Finnish, French, German, Italian, Japanese, Norwegian, Portuguese, Brazilian-Portuguese, Russian, Spanish, Swedish, Turkish, Vietnamese
DLCO
10% helium, ± 10%, 0.3% carbon monoxide, ± 10%, 18 to 25% oxygen (normally 21%), balance nitrogen
MBW
Oxygen for hospital use
Printing options
PCL standard, direct to printer or over network
Data management
EasyWare Pro (SQLite, MS SQL Server)
Export/EMR
HL7, XML, GDT, via USB, LAN Network
Hardware Interface
Ethernet port, USB, possibility to upgrade to WLAN
No. of tests
> 10‘000 tests
Age range
Spirometry > 4 years, DLCO > 6 years, MBW > 4 years or > 18 kg
Dimensions
27 x 33.5 x 27 cm3 (H x W x D), 8 kg
Device classification
Protection class I, Type BF applied part
Operating conditions
Temp 10-40 °C/ 50-104 °F, Rel. Humidity 30-75%, no condensation, Atmosph. Pressure 700 - 1060 hPa
Power Consumption
50 VA
FVC
ATI, BEV, EOTV, FEF10, FEF25, FEF 2575, FEF2575_6, FEF40, FEF50, FEF50/FVC, FEF50/VCmax, FEF60, FEF75, FEF75-85, FEF80, FET, FET25-75, FEV.25, FEV.5, FEV.5/FVC, FEV.75, FEV.75/FEV6, FEV.75/FVC, FEV.75/VCmax, FEV1, FEV1/FEV6, FEV1/FVC, FEV1/FVC6, FEV1/VCmax, FEV1/VCext, FEV3/FVC, FEV3/VCmax, FEV3, FEV6, FVC, FVC6, MEF20, MEF25, MEF40, MEF50, MEF60, MEF75, MEF90, MMEF, MTC1, MTC2, MTC3, MTCR, PEF, PEFT, t0, VCext, VCmax
FVL
ATI, BEV, CVI, E50/150, EOTV, FEF10. FEF25, FEF2575, FEF2575_6, FEF40, FEF50, FEF50/FVC, FEF50/VCmax, FEF60, FEF75, FEF75-85, FEF80, FET, FET25-75, FEV.25, FEV.5, FEV.5/FVC, FEV.75, FEV.75/FEV6, FEV.75/FVC, FEV.75/VCmax, FEV1, FEV1/FEV6, FEV1/FIV1, FEV1/FVC, FEV1/VCmax, FEV1/VCext, FEV3/FVC, FEV3/VCmax, FEV3, FEV6, FIF25,FIF50, FIF50/FEF50, FIF75, FIV.25, FIV.5, FIV1, FIVC, FVC, MEF20, MEF25, MEF40, MEF50, MEF60, MEF75, MEF90,MIF25, MIF50, MIF75, MMEF, MTC1, MTC2, MTC3, MTCR, PEF, PEFT, PIF, t0, VCext, VCmax
SVC
ERV, IC, IRV, Rf, VC, VCex, VCext, VCin, VCmax, VT
MVV
MVV, MVV6, MVVtime, VT
DLCO
BHT, COHb, ColBarVol, CO Conc, HE Conc, O2 Conc, Anatomic Dead Space, System Dead Space, Discard Volume, DLadj, DLadj/VA, DLCO, DLCO/VA (KCO), FA CO, FA HE, FE CO, FEV1/FVC, FI CO, FI HE, FRC sb, FRC Cor, Hb, tI, Kroghs K, PAO2, RV sb, RV Cor, RV/TLC, RV/TLC Cor, TLC sb, TLC Cor, TLCO, VA sb, VA Cor, VCext, VCmax, Vd, VI
MBW
CEV, CEV5, Anatomic Dead Space, Syst Dead Space, ERV, FRC base, FRC extrapol, FRC mb, IRV, LCI, LCI5, MO, MR1, MR2, RV mb, RV/TLC mb, TLC mb, VA mb, VC, VCex, VCin, Vd, VT, VT/FRC mb, VT/kg, Scond, Sacin
GLI
Stanojevic 2009, Quanjer 2012
North America
NHANES III (Hankinson) 1999, Knudson 1983, Knudson 1976, Crapo 1981, Morris 1971 & 1976, Hsu 1979, Dockery (Harvard) 1993, Polgar 1971, Gutierrez (Canada) 2004, Eigen 2001
Latin America
Pereira 1992, Perreira 2006 & 2008, Pérez-Padilla (PLATINO) 2006, Pérez-Padilla (Mexico) 2001, Pérez-Padilla (Mexico, Pediatrics) 2003, Chile 2010, Chile (Pediatrics) 1997
Europe
ERS (ECCS, EGKS, Quanjer) 1993, Zapletal 1977, Zapletal 2003, Rosenthal 1993, Austria 1988, Austria 1994, Sapaldia (Switzerland) 1996, Roca (Spain, SEPAR) 1982, Garcia-Rio (SEPAR) 2013, Vilozni 2005, Falaschetti 2004, Klement (Russia) 1986
Europe Scandinavia
Hedenström 1985 & 1986, Gulsvik (Norway) 1985, Berglund Birath (Sweden) 1963, Langhammer (Norway) 2001, Finnish 1982 (1998), Nystad 2002
Australia
Hibbert 1989, Gore Crockett 1995
Asia
Chhabra (India) 2014, Dejsomritrutai (Thailand) 2000, Indonesia 1992, IP (China, HongKong) 2000 & 2006, JRS 2001 & 2014
Africa
Ethiopia 1985
North America
Ayers 1975, Burrows 1961, Crapo 1981 & 1982, Goldman Becklake 1958, Knudson 1987, McGrath Thompson 1959, Miller 1980, Gutierrez (Canada) 2004, NHANES (Neas) 1996, Polgar 1971
Latin America
Vazquez Garcia (ALAT) 2016
Europe
ERS (Quanjer) 1993, Zapletal 1977, Roca 1990 & 1998, Hedenström 1985 & 1986, Gulsvik 1992, Klement (Russia) 1986
Other
Pereira 2008, Thompson 2008, Kim 2012, Chhabra (India) 2015), Ip (China, HongKong) 2007, JRS (Japan) 2001
Europe
Verbanck 2012
Type
Ultrasonic transit time
Flow Range
± 16 l/s
Flow Resolution
4 ml/s
Flow Accuracy(except PEF)
± 2% or 0.02 l/s
Volume Resolution
1 ml
Volume Accuracy
± 2% or 0.050 l
PEF Accuracy
± 5% or 0.200 l/s
MVV Accuracy
± 5% or 5 l/min
Resistance
~ 0.3 cm H2O/l/s at 16 l/s
Sample Rate
400 Hz
CO
CO2
Type
Non-dispersive infrared
Range
0 to 0.35%
0 to 15%
Resolution
0.0001%
0.005 %
Accuracy
± 0.001%
0 to 5%: ± 0.05%
Helium
N2
Type
Ultrasonic transit time
Range
0 to 50%
0 to 100%
Resolution
0.02%
0.1%
Accuracy
0.05%
0.2%
Part Numbers
Description
3100-1
EasyOne Pro LAB Respiratory Analysis System
Part Num
Description
2050-1
Case of 50 Spirette mouthpieces
2050-6
Case of 75 Spirette mouthpieces
2050-5
Case of 200 Spirette mouthpieces
2050-10
Case of 500 Spirette mouthpieces
3050-1
Case of 50 DLCO Barriette for EasyOne Pro and LAB
3050-2
Case of 100 DLCO Barriette for EasyOne Pro and LAB
3150-1
Case of 40 FRC Barriette for EasyOne Pro LAB
3150-2
Case of 80 FRC Barriette for EasyOne Pro LAB

Spirette FA Pro/LAB Specifications

Product
Spirette FA Pro/LAB
Compatible with ndd products
EasyOne Pro and EasyOne Pro/LAB with Software Version V03.07.01.09 (or higher)
Compatible with filter
U.S. & International customers: To learn more about compatible inline filter solutions available in your region, please use the contact us form.
Transport and storage conditions
Temperature: –20 to 50° C Humidity: 5 to 95% Pressure: 400 to 1060 hPa
Dimensions
31 x 38 x 141 mm
Weight
11g 
Material Spirette FA Pro/LAB
Linear Low-Density Polyethylene, Polypropylene (LLDPE and PP)
Material Bag 
Polyethylene